![]() ![]() ![]() Dimensions are shown for
reference only.
RADIUS POWER www.radiuspower.com
Specifications are subject to
change. Standard & Custom Products PH 714-289-0055
FAX 714-289-2149
Specifications
Operating Freq.: DC - 60Hz
Operating Voltage: 250V +10%
Ambient Temperature: 40
oC
Inrush Rating: 20x (10ms), 1.5x (1.5min)
Climatic Category : 25/100/21
Hipot Rating: 2500VDC (P/N - E)
Safety Approvals: cCSAus/UR/EN133200
Part Number / Ordering
RP192
-X
(Amps)
-Y
(Ycap, nF)
1
0
3
.22
6
.47
10
1
2.2
3.3
4.7
Note: Use any Y (Ycap) with any X (Amps) rating
Leakage Current
Ycap, nF
mA,
120V/60HZ
mA,
250V/50HZ
0
0
0
.22
.02
.035
.47
.042
.074
1
.09
.15
2.2
.2
.35
3.3
.3
.52
4.7
.42
.74
Schematic
LINE LOAD
RP192
HIGH PERFORMANCE TO 10A
PCB FILTER
ROHS COMPLIANT
RP192 Series Hi-Perf PCB 1-Stage Power Line
![]() ![]() Dimensions are shown for
reference only.
RADIUS POWER www.radiuspower.com
Specifications are subject to
change. Standard & Custom Products PH 714-289-0055
FAX 714-289-2149
1 AMP
FREQ(MHz
)
.15
.5
1
10
30
CM, dB
45
50
50
45
45
DM, dB
65
70
70
60
55
3 AMP
FREQ(MHz
)
.15
.5
1
10
30
CM, dB
40
45
45
40
40
DM, dB
55
75
75
60
55
6 AMP
FREQ(MHz
)
.15
.5
1
10
30
CM, dB
30
42
45
50
45
DM, dB
42
65
65
55
55
10 AMP
FREQ(MHz
)
.15
.5
1
10
30
CM, dB
20
30
40
45
40
DM, dB
35
55
60
50
50
RP192 Typical Insertion Loss, 50/50ohm Mechanicals
|