![]() ![]() Dimensions are shown for reference
only.
RADIUS POWER www.radiuspower.com
Specifications are subject to
change. Standard & Custom Products PH 714-289-0055
FAX 714-289-2149
Specifications
Operating Freq.: 50/60Hz
Operating Voltage: 250V +10%
Ambient Temperature: 40
oC
Inrush Rating: 20x (10ms), 1.5x (1.5min)
Climatic Category : 25/100/21
Hipot Rating: 2200VDC (L/N - E)
Terminals: Inlet & 0.187 Quick Disconnect Tabs
Safety Approvals: UR/cCSAus/EN133200
Part Number / Ordering
RP182CD
-X
(Amps)
-Y
(Ycap, nF)
3
0
6
.22
10
.47
1
2.2
3.3
4.7
10
Note: Use any Y (Ycap) with any X (Amps) rating
e.g. RP182CD-3-4.7
3 Amps with 4.7nF y-caps
Leakage Current
Ycap
mA, 120V/60HZ
mA, 250V,50HZ
0
0
0
.22
.02
.035
.47
.042
.074
1
.09
.15
2.2
.2
.35
3.3
.3
.52
4.7
.42
.74
10
.85
1.5
Schematic
LINE
LOAD
RP182CD
High Performance TO 10A
IEC INLET
ROHS COMPLIANT
RP182CD Series IEC Inlet Dual Stage Power Line
![]() ![]() Dimensions are shown for reference
only
RADIUS POWER www.radiuspower.com
Specifications are
subject to change. Standard & Custom Products PH 714-289-0055
FAX 714-289-2149
3 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
55
60
70
60
35
DM, dB
30
70
56
56
60
6 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
48
56
60
55
40
DM, dB
16
50
60
55
60
10 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
48
55
62
55
40
DM, dB
16
50
65
65
68
RP182CD Typical Insertion Loss, 50/50ohm Mechanicals
|