Filter
     Dimensions shown for reference only.               
RADIUS POWER                  www.radiuspower.com
     Specifications subject to change.                  Standard & Custom Products               PH 714-289-0055
                                                                                                                                FAX 714-289-214
Specifications
Operating Freq.:  DC - 60Hz
Operating Voltage: 250V +10%
Ambient Temperature: 40
oC
Inrush Rating:  20x (10ms), 1.5x (1min)
Climatic Category : 25/100/21
Hipot Rating: 2500VDC (P/N - E)
Terminals: .250 Quick Disconnect Tabs
Safety Approvals: cCSAus/UR/EN133200
Typical Insertion Loss, dB (50/50ohm)
FREQ(MHZ)
.15
.5
1.0
10
30
CM(dB)
42
65
70
55
50
DM(dB)
36
60
65
70
70
Part Number / Ordering
DSC2000
-Y
(Ycap,nF)
-Z
(Ycap,nF)
LK, mA
250V/50HZ
0
0
0
.22
.22
.07
.47
.47
.15
1
1
.3
2.2
2.2
.7
3.3
3.3
1.0
4.7
4.7
1.5
6.8
6.8
2.2
10
10
3.0
Note: Use any combination of –Y and -Z
   
               
Schematic
LINE                                                        LOAD
   
               
Mechanical
                       
A
B
C
MTG HOLE
4.06
2.2
1.8
.2
DSC2000
20A CHASSIS MOUNT FILTER
ROHS COMPLIANT
DSC2000                            High Performance Dual Stage Power Line