Dimensions shown for reference only.               
RADIUS POWER                  www.radiuspower.com
     Specifications subject to change.                  Standard & Custom Products               PH 714-289-0055
                                                                                                                                FAX 714-289-214
Specifications
Operating Freq.: DC - 60Hz
Operating Voltage: 250V +10%
Ambient Temperature: 40
oC
Inrush Rating: 20x (10ms), 1.5x (1.5min)      
Climatic Category : 25/85/21
Hipot Rating: 2200VDC (P/N - E)
Terminals: .250 QD Tabs
Plastic Mtg Force: 18 LBS
Safety Approvals: UR/CSA/EN133200
Part Number / Ordering
RP150
-X
(Amps)
-T
1
QD
3
6
10
   
                
Leakage Current
120V/60HZ: 300uA
   250/50HZ: 520uA
Schematic
LINE                                                      LOAD
RP150
IEC INLET TO 10A
ROHS COMPLIANT
RP150 Series                                          IEC Inlet 1-Stage Power Line Filter
     Dimensions shown for reference only.               
RADIUS POWER                  www.radiuspower.com
     Specifications subject to change.                  Standard & Custom Products               PH 714-289-0055
                                                                                                                                FAX 714-289-214
1 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
40
52
50
52
40
DM, dB
22
32
56
52
40
                     
     
3 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
36
45
48
52
30
DM, dB
20
32
50
58
32
10 AMP
    
6 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
20
28
32
52
42
DM, dB
18
28
32
55
38
FREQ(MHz)
.15
.5
1
10
30
CM, dB
26
35
38
58
30
DM, dB
20
30
36
55
34
RP150 Typical Insertion Loss, 50/50ohm                 Mechanicals